Starlet Quad

Characteristics:

  • IP20 protection rating
  • Housing colors available: white or black
  • Power supply voltage: 230V AC 50Hz (for MT, AT and CT) or 230V AC 50Hz / 220V DC (for CB)
  • Light source: efficient high power LED
  • Functions: NM – non-maintained or M – maintained version
  • Autonomy times: 1h, 2h or 3h
  • Batteries applied: NiCD or NiMH
  • Optics: SO – open spaces, SQ – square beam open spaces, SOH – high open spaces, SC – corridors, SCH – high corridors or SP – safety points
  • Testing options: MT – manual test, AT – auto test, CT – central test (Wells) or CB – central battery version
  • Installation methods: on ceiling (surface) or in ceiling (recessed)
  • CRI index: Ra>=70
  • Temperature working range: ta 0°C ÷ 40°C, for CB version ta -20°C ÷ 40°C
  • Minimum LED lifetime: 50 000

Additional accessories

Files to download

Variants available

Catalogue number Name Application of the luminaires Function Test Autonomy Mounting method IP Emergency luminous flux Mains luminous flux Housing color Total power Accessories
86481 SP 250 M 1H AT Optics for safety points (SP) Maintained (SA/M) AT – auto test 1H Surface (NT) IP20 258 lm 258 lm White 6W
86487 SP 250 M 1H AT [BLK] Optics for safety points (SP) Maintained (SA/M) AT – auto test 1H Surface (NT) IP20 258 lm 258 lm Black 6W
92854 SOH 250 M 1H AT High open spaces / antipanic luminaires (SOH) Maintained (SA/M) AT – auto test 1H Surface (NT) IP20 262 lm 262 lm White 6W
92980 SOH 250 M 1H AT [BLK] High open spaces / antipanic luminaires (SOH) Maintained (SA/M) AT – auto test 1H Surface (NT) IP20 262 lm 262 lm Black 6W
92954 SCH 250 M 1H AT Optics for evacuation routes / high corridors (SCH) Maintained (SA/M) AT – auto test 1H Surface (NT) IP20 240 lm 240 lm White 6W
92884 SCH 250 M 1H AT [BLK] Optics for evacuation routes / high corridors (SCH) Maintained (SA/M) AT – auto test 1H Surface (NT) IP20 240 lm 240 lm Black 6W
92829 SO 250 NM 2H AT Open spaces / antipanic luminaires (SO) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 263 lm - White 2,5W
87497 SO 250 NM 2H AT [BLK] Open spaces / antipanic luminaires (SO) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 263 lm - Black 2,5W
86584 SQ 250 NM 2H AT Square beam open spaces optics / antipanic luminaires (SQ) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 277 lm - White 2,5W
86590 SQ 250 NM 2H AT [BLK] Square beam open spaces optics / antipanic luminaires (SQ) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 277 lm - Black 2,5W
92929 SC 250 NM 2H AT Optics for evacuation routes / corridors (SC) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 254 lm - White 2,5W
87466 SC 250 NM 2H AT [BLK] Optics for evacuation routes / corridors (SC) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 254 lm - Black 2,5W
86492 SP 250 NM 2H AT Optics for safety points (SP) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 258 lm - Black 2,5W
86498 SP 250 NM 2H AT [BLK] Optics for safety points (SP) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 258 lm - White 2,5W
92859 SOH 250 NM 2H AT High open spaces / antipanic luminaires (SOH) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 262 lm - White 2,5W
87446 SOH 250 NM 2H AT [BLK] High open spaces / antipanic luminaires (SOH) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 262 lm - Black 2,5W
92959 SCH 250 NM 2H AT Optics for evacuation routes / high corridors (SCH) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 240 lm - White 2,5W
87435 SCH 250 NM 2H AT [BLK] Optics for evacuation routes / high corridors (SCH) Non-maintained (A/NM) AT – auto test 2H Surface (NT) IP20 240 lm - Black 2,5W
92830 SO 250 M 2H AT Open spaces / antipanic luminaires (SO) Maintained (SA/M) AT – auto test 2H Surface (NT) IP20 263 lm 263 lm White 7W
87498 SO 250 M 2H AT [BLK] Open spaces / antipanic luminaires (SO) Maintained (SA/M) AT – auto test 2H Surface (NT) IP20 263 lm 263 lm Black 7W