Luminaires with given parameters
Catalogue number | Name | Application of the luminaires | Function | Test | Autonomy | Mounting method | IP | Emergency luminous flux | Mains luminous flux (lm) | Housing color | Total power | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|
93808 | VELLA SC 125 NM 1H MT IP65 |
Optics for evacuation routes / corridors (SC) | Non-maintained (A/NM) | MT – manual test | 3H | Surface (NT) | IP65 | 145 lm | - | White | 1,5W |
|
93140 | WARS 2x120 M 2H AT 4000K IP65 |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | AT – auto test | 2H | Surface (NT) | IP65 | 1281 lm | 4599 lm | Other | 52W |
|
91495 | Orion II 100 M 3H MT LT IP65 |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) + LT (low temperatures) | MT – manual test | 3H | Surface (NT) | IP65 | 122 lm | 122 lm | White | 14W |
|
86454 | Starlet Quad SP 150 NM 2H MT |
Optics for safety points (SP) | Non-maintained (A/NM) | MT – manual test | 2H | Surface (NT) | IP20 | 158 lm | - | White | 1,5W |
|
86270 | Starlet Round SP 150 NM 2H MT |
Optics for safety points (SP) | Non-maintained (A/NM) | MT – manual test | 2H | Surface (NT) | IP20 | 158 lm | - | White | 1,5W |
|
95610 | Suprema NT SQ 350 M 3H AT IP54 NT |
Square beam open spaces optics / antipanic luminaires (SQ) | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP54 | 427 lm | 427 lm | White | 10W |
|
90085 | Directo S M 3H AT [BLK] |
Directional luminaires | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP20 | - | - | Black | 3W |
|
89795 | Orion II 250 M 3H MT LT IP65 [BLK] |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) + LT (low temperatures) | MT – manual test | 3H | Surface (NT) | IP65 | 294 lm | 295 lm | Black | 18W |
|
89700 | Orion II 150 M 3H MT LT IP65 [BLK] |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) + LT (low temperatures) | MT – manual test | 3H | Surface (NT) | IP65 | 183 lm | 183 lm | Black | 13W |
|
93659 | VELLA SC 125 NM 1H MT IP65 [BLK] |
Optics for evacuation routes / corridors (SC) | Non-maintained (A/NM) | MT – manual test | 3H | Surface (NT) | IP65 | 145 lm | - | Black | 1,5W |
|
95652 | Suprema PT SQ 350 M 3H AT IP54 PT [BLK] |
Square beam open spaces optics / antipanic luminaires (SQ) | Maintained (SA/M) | AT – auto test | 3H | Recessed (PT) | IP54 | 427 lm | 427 lm | Black | 10W | - |
89495 | Orion II 100 M 3H MT LT IP65 [BLK] |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) + LT (low temperatures) | MT – manual test | 3H | Surface (NT) | IP65 | 122 lm | 122 lm | Black | 14W |
|
86460 | Starlet Quad SP 150 NM 2H MT [BLK] |
Optics for safety points (SP) | Non-maintained (A/NM) | MT – manual test | 2H | Surface (NT) | IP20 | 158 lm | - | Black | 1,5W |
|
93146 | WARS 2x120 M 3H AT 4000K IP65 |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP65 | 1281 lm | 4599 lm | Other | 52W |
|
95638 | Suprema NT SQ 350 M 3H AT IP54 NT [BLK] |
Square beam open spaces optics / antipanic luminaires (SQ) | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP54 | 427 lm | 427 lm | Black | 10W |
|
86276 | Starlet Round SP 150 NM 2H MT [BLK] |
Optics for safety points (SP) | Non-maintained (A/NM) | MT – manual test | 2H | Surface (NT) | IP20 | 158 lm | - | Black | 1,5W |
|
91874 | Starlet Round SO 150 M 2H MT |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | MT – manual test | 2H | Surface (NT) | IP20 | 171 lm | 171 lm | White | 4W |
|
91778 | Orion II 100 NM 1H AT |
Open spaces / antipanic luminaires (SO) | Non-maintained (A/NM) | AT – auto test | 1H | Surface (NT) | IP65 | 122 lm | - | White | 1,5W |
|
90480 | Directo S NM 1H CT |
Directional luminaires | Non-maintained (A/NM) | CT – central test / Wells system | 1H | Surface (NT) | IP20 | - | - | White | 1,5W |
|
91538 | Orion II 150 NM 1H AT |
Open spaces / antipanic luminaires (SO) | Non-maintained (A/NM) | AT – auto test | 1H | Surface (NT) | IP65 | 183 lm | - | White | 1,5W |
|
93675 | VELLA SO 125 M 1H MT IP65 |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | MT – manual test | 1H | Surface (NT) | IP65 | 158 lm | 158 lm | White | 3,5W |
|
91628 | Orion II 250 NM 1H AT IP65 |
Open spaces / antipanic luminaires (SO) | Non-maintained (A/NM) | AT – auto test | 1H | Surface (NT) | IP65 | 294 lm | - | White | 1,5W |
|
92808 | Starlet Quad SO 150 M 2H MT |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | MT – manual test | 2H | Surface (NT) | IP20 | 155 lm | 155 lm | White | 4W |
|
94744 | Suprema PT SC 350 M 3H AT IP54 PT |
Optics for evacuation routes / corridors (SC) | Maintained (SA/M) | AT – auto test | 3H | Recessed (PT) | IP54 | 374 lm | 374 lm | White | 3,5W | - |
94724 | Suprema NT SC 350 M 3H AT IP54 NT |
Optics for evacuation routes / corridors (SC) | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP54 | 374 lm | 374 lm | White | 3,5W |
|
93141 | WARS 1x150 M 2H AT 4000K IP65 |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | AT – auto test | 2H | Surface (NT) | IP65 | 1390 lm | 4936 lm | Other | 52W |
|
93147 | WARS 1x150 M 3H AT 4000K IP65 |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP65 | 1390 lm | 4936 lm | Other | 52W |
|
90874 | Starlet Round SO 150 M 2H MT [BLK] |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | MT – manual test | 2H | Surface (NT) | IP20 | 171 lm | 171 lm | Black | 4W |
|
89778 | Orion II 100 NM 1H AT [BLK] |
Open spaces / antipanic luminaires (SO) | Non-maintained (A/NM) | AT – auto test | 1H | Surface (NT) | IP65 | 122 lm | - | Black | 1,5W |
|
90180 | Directo S NM 1H CT [BLK] |
Directional luminaires | Non-maintained (A/NM) | CT – central test / Wells system | 1H | Surface (NT) | IP20 | - | - | Black | 1,5W |
|
93658 | VELLA SO 125 M 1H MT IP65 [BLK] |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | MT – manual test | 1H | Surface (NT) | IP65 | 158 lm | 158 lm | Black | 3,5W |
|
89538 | Orion II 150 NM 1H AT [BLK] |
Open spaces / antipanic luminaires (SO) | Non-maintained (A/NM) | AT – auto test | 1H | Surface (NT) | IP65 | 183 lm | - | Black | 1,5W |
|
87510 | Starlet Quad SO 150 M 2H MT [BLK] |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | MT – manual test | 2H | Surface (NT) | IP20 | 155 lm | 155 lm | Black | 4W |
|
89628 | Orion II 250 NM 1H AT IP65 [BLK] |
Open spaces / antipanic luminaires (SO) | Non-maintained (A/NM) | AT – auto test | 1H | Surface (NT) | IP65 | 294 lm | - | Black | 1,5W |
|
88732 | Suprema NT SC 350 M 3H AT IP54 NT [BLK] |
Optics for evacuation routes / corridors (SC) | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP54 | 374 lm | 374 lm | Black | 3,5W |
|
88724 | Suprema PT SC 350 M 3H AT IP54 PT [BLK] |
Optics for evacuation routes / corridors (SC) | Maintained (SA/M) | AT – auto test | 3H | Recessed (PT) | IP54 | 374 lm | 374 lm | Black | 3,5W | - |
93142 | WARS 2x150 M 2H AT 4000K IP65 |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | AT – auto test | 2H | Surface (NT) | IP65 | 1685 lm | 5828 lm | Other | 63W |
|
86777 | VELLA SO 125 M 1H MT IP65 LT |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) + LT (low temperatures) | MT – manual test | 1H | Surface (NT) | IP65 | 158 lm | 158 lm | White | 14W |
|
90481 | Directo S M 1H CT |
Directional luminaires | Maintained (SA/M) | CT – central test / Wells system | 1H | Surface (NT) | IP20 | - | - | White | 2,5W |
|
86361 | Starlet Round SQ 150 M 2H MT |
Square beam open spaces optics / antipanic luminaires (SQ) | Maintained (SA/M) | MT – manual test | 2H | Surface (NT) | IP20 | 166 lm | 166 lm | White | 4W |
|
91779 | Orion II 100 M 1H AT |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP65 | 122 lm | 122 lm | White | 3W |
|
86547 | Starlet Quad SQ 150 M 2H MT |
Square beam open spaces optics / antipanic luminaires (SQ) | Maintained (SA/M) | MT – manual test | 2H | Surface (NT) | IP20 | 161 lm | 161 lm | White | 4W |
|
91539 | Orion II 150 M 1H AT |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP65 | 183 lm | 183 lm | White | 4W |
|
94717 | Suprema NT SCH 350 NM 3H AT IP54 NT |
Optics for evacuation routes / high corridors (SCH) | Non-maintained (A/NM) | AT – auto test | 3H | Surface (NT) | IP54 | 380 lm | - | White | 3,5W |
|
91629 | Orion II 250 M 1H AT IP65 |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | AT – auto test | 1H | Surface (NT) | IP65 | 294 lm | 295 lm | White | 6W |
|
94767 | Suprema PT SCH 350 NM 3H AT IP54 PT |
Optics for evacuation routes / high corridors (SCH) | Non-maintained (A/NM) | AT – auto test | 3H | Recessed (PT) | IP54 | 380 lm | - | White | 3,5W | - |
86781 | VELLA SO 125 M 1H MT IP65 LT [BLK] |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) + LT (low temperatures) | MT – manual test | 1H | Surface (NT) | IP65 | 158 lm | 158 lm | Black | 14W |
|
93148 | WARS 2x150 M 3H AT 4000K IP65 |
Open spaces / antipanic luminaires (SO) | Maintained (SA/M) | AT – auto test | 3H | Surface (NT) | IP65 | 1685 lm | 5828 lm | Other | 63W |
|
90181 | Directo S M 1H CT [BLK] |
Directional luminaires | Maintained (SA/M) | CT – central test / Wells system | 1H | Surface (NT) | IP20 | - | - | Black | 2,5W |
|
86367 | Starlet Round SQ 150 M 2H MT [BLK] |
Square beam open spaces optics / antipanic luminaires (SQ) | Maintained (SA/M) | MT – manual test | 2H | Surface (NT) | IP20 | 166 lm | 166 lm | Black | 4W |
|